×
Did you know that Comet exists in a US version as well?
dataloggers, thermometers, hygrometers...
English Česky Africa China Español Français Magyar Polski Sweden USA

IoT Wireless Datalogger for 3 current inputs 0-20mA and 1 two-state input, with built-in 2G modem

GSM datalogger is designed to record 3 current inputs and 1 binary input. In case of exceeded set limits, SMS and JSON messages can be sent via GPRS data connection. Measured values can be sent to the internet storage COMET Cloud, which is a complete monitoring, alarm and analysis system.

It is also possible to set the regular sending of JSON messages to COMET Database, the sending interval is adjustable. Alarms are also indicated locally by LED, LCD and acoustically by built-in beeper.
The recording is performed in a non-volatile electronic memory. The data can be transferred to a PC via included USB-C cable.

GSM recorder includes Traceable calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.

 

  • code
    U6841M
  • Warranty
    3 years

Technical data

Measured value

Current
Two-state signal

CURRENT INPUT

Measuring range 0 to 20 mA DC
Resolution better than 1 µA
Accuracy ±20 µA
Input resistance approx. 100 Ω
Minimum current 0 mA (open circuit)
Maximum current limited to approx. 40 mA

BINARY INPUT

Parameters of the voltage contact „L“ level input voltage:< 0,8 V(*);
„H“ level input voltage:> 2 V;
Minimum voltage applicable:0 V;
Maximum voltage applicable:+30 V DC
Parameters of the voltage-free contact Contact resistance in „switched-on“ state:< 10 kOhm;
Contact resistance in the „switched-off“ state:> 2 MOhm;
Contact voltage in the „switched-off“ state:ca 3 V;
Minimum state duration necessary for latching the state:1s

GSM MODEM PARAMETERS

Quad-band 850/900/1800/1900MHz
Compliant to GSM Phase2/2+
GPRS GPRS mobile station class B
Class 4 2W @ 850/900MHz
Class 1 1W @ 1800/1900MHz

GENERAL TECHNICAL DATA

Operating temperature -20 to +60 °C
Channels 3x current input, 1x binary input
Memory 500,000 values in noncyclic logging mode; 350,000 values in cyclic record mode
Recording interval to the internal memory adjustable from 1 second to 24 hours
Recording interval to the COMET Cloud from 5 minutes
Interval for measuring and evaluating alarms adjustable 1 s, 10 s, 1 min
Recording mode noncyclic - data logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Real time clock year, leap year, month, day, hour, minute, second
Power rechargeable Li-Ion battery A8200, 3.6V/5200mAh
Protection class IP20
Dimensions 61 x 93 x 53 mm, with antenna 120 x 93 x 53 mm
Weight (including batteries) approx. 270 g
Warranty 3 years

Optional accessories and download

AC/DC adapter 230Vac to 5Vdc/2.1 A, EU

AC/DC adapter 230Vac to 5Vdc/2.1 A, EU

code A1879eu
AC/DC adapter 230Vac to 5Vdc/2.1 A, UK

AC/DC adapter 230Vac to 5Vdc/2.1 A, UK

code A1879uk
AC/DC adapter 230Vac to 5Vdc/2.1 A, US

AC/DC adapter 230Vac to 5Vdc/2.1 A, US

code A1879us
Accupack A8205 for dataloggers "U"

Accupack A8205 for dataloggers "U"

code A8205

USB-C cable, 1 meter

USB-C cable, 1 meter

code MP053

wall holder for datalogger - kopie

wall holder for datalogger - kopie

code LP100
Holder for mounting the GSM or CO2 Datalogger on magnetic surfaces

Holder for mounting the GSM or CO2 Datalogger on magnetic surfaces

code LP103

COMET Database

COMET Database

code CDB
COMET Cloud

COMET Cloud

code cloud

code cloud_app
COMET Vision - Software for Dataloggers and Multiloggers

COMET Vision - Software for Dataloggers and Multiloggers

code CV
Database Viewer for Comet Database

Database Viewer for Comet Database

code DBV

Magnetic door contact SA-200-A

Magnetic door contact SA-200-A

code SA200A
Magnetic door contact with cable length 10m

Magnetic door contact with cable length 10m

code SA200A-10
Magnetic door contact with cable length 15m

Magnetic door contact with cable length 15m

code SA200A-15
Magnetic door contact with cable length 2m

Magnetic door contact with cable length 2m

code SA200A-2
Magnetic door contact with cable length 20m

Magnetic door contact with cable length 20m

code SA200A-20
Magnetic door contact with cable length 30m

Magnetic door contact with cable length 30m

code SA200A-30
Magnetic door contact with cable length 5m

Magnetic door contact with cable length 5m

code SA200A-5
Power detector SP008

Power detector SP008

code SP008

code LP105
Connection adapter for Ux841 dataloggers

Connection adapter for Ux841 dataloggers

code LP106

Software

download-icon Comet Vision Software (2.3.8801.28020 dbapi 21.1)
16.23 MB
download-icon Comet Database One Click Installer (21.1-II)
487.31 MB
download-icon Conversions - application for recalculation of values
694.50 KB
download-icon COMET Cloud Lite - Android (Google Play)
download-icon COMET Cloud Lite - iOS (App Store)

Others

download-icon Terms and Conditions COMET System s.r.o.
133.12 KB

Manuals

download-icon Instruction Manual
3.29 MB
download-icon Quick Start Manual
1.08 MB
download-icon Safety Information
335.90 KB
download-icon Manual for Calibration (accuracy verification) and Adjustment for Dataloggers Uxxxx(M)
427.80 KB
download-icon Declaration of Conformity
96.91 KB

Catalogs

download-icon CATALOG - Dataloggers
3.57 MB
download-icon CATALOG - GSM loggers
3.00 MB

Related products

COMET Cloud

COMET Cloud

code cloud
COMET Database

COMET Database

code CDB
Connection adapter for Ux841 dataloggers

Connection adapter for Ux841 dataloggers

code LP106
IoT Wireless Temperature Datalogger with built-in sensor and 2G modem

IoT Wireless Temperature Datalogger with built-in sensor and 2G modem

code U0110M
IoT Wireless Temperature Datalogger for 4 external probes, with built-in 2G modem

IoT Wireless Temperature Datalogger for 4 external probes, with built-in 2G modem

code U0141M
IoT Wireless Temperature Datalogger for 2 external probes, with two two-state inputs, built-in 2G modem

IoT Wireless Temperature Datalogger for 2 external probes, with two two-state inputs, built-in 2G modem

code U0843M
IoT Wireless Temperature and Relative Humidity Datalogger, with built-in 2G modem

IoT Wireless Temperature and Relative Humidity Datalogger, with built-in 2G modem

code U3120M
IoT Wireless Temperature and Relative Humidity Datalogger for external probe, with built-in 2G modem

IoT Wireless Temperature and Relative Humidity Datalogger for external probe, with built-in 2G modem

code U3121M
IoT Wireless Temperature and Relative Humidity Datalogger with connector for other temperature probe, with built-in 2G modem

IoT Wireless Temperature and Relative Humidity Datalogger with connector for other temperature probe, with built-in 2G modem

code U3631M
IoT Wireless Temperature, Relative Humidity, CO2 and atmospheric pressure Datalogger with built-in 2G modem

IoT Wireless Temperature, Relative Humidity, CO2 and atmospheric pressure Datalogger with built-in 2G modem

code U4440M
IoT Wireless Four channel Datalogger with pulse and two-state inputs, with built-in 2G modem

IoT Wireless Four channel Datalogger with pulse and two-state inputs, with built-in 2G modem

code U7844M
IoT Wireless CO2 datalogger with built-in sensor, 2G modem

IoT Wireless CO2 datalogger with built-in sensor, 2G modem

code U8410M
Wireless thermometer, hygrometer barometer, síť Sigfox IoT

Wireless thermometer, hygrometer barometer, síť Sigfox IoT

code W7810